Launch offer — valid today only

📄 Digital book in PDF · read it on your phone or print it

Sprinkler Inspection in Drawings: Every Valve, Gauge and Test in the Same Order One Topic on Every Page

Risers, OS&Y valves, gauges, the main drain, the inspector's test, dry pipe valves, heads, fire pumps and impairments, checked against the 2023 edition of NFPA 25. One topic per page: the drawing first, then what you need to remember. 63 illustrated pages.

START STUDYING THIS WAY

🔒 Secure checkout · PDF by email · 30-day guarantee

Every topic, its own pageEvery valve, gauge and test drawn, with the explanation right next to it
63 illustrated pages9 parts, from the riser at a glance to the night-before checklist
Up-to-date sourcesNFPA 25 (2023 edition), NFPA 13 and NFPA 20
PDF by emailFormat

Look Inside the Book

Every page has one big drawing and a box with the numbers, intervals and steps you need to know:

Inspect = look · Test = operate and measure · Maintain = fix. The owner is responsible.
Inspect = look · Test = operate and measure · Maintain = fix. The owner is responsible.
Quarterly = 2–4 months apart · Semiannual = 4–8 · Annual = 9–15
Quarterly = 2–4 months apart · Semiannual = 4–8 · Annual = 9–15
OS&Y: stem out = open, stem flush = closed, plus the 5 inspection points
OS&Y: stem out = open, stem flush = closed, plus the 5 inspection points
Supply, system and air gauges: where they sit and the 2023 check intervals
Supply, system and air gauges: where they sit and the 2023 check intervals
Vane and pressure waterflow switches: semiannual test, retard set per manufacturer, signal within 90 s.
Vane and pressure waterflow switches: semiannual test, retard set per manufacturer, signal within 90 s.
Dry pipe valve in section: air on the big area, water on the small seat, enclosure at 40°F or above.
Dry pipe valve in section: air on the big area, water on the small seat, enclosure at 40°F or above.
At least 18 inches between deflectors and storage, drawn as a blocked spray.
At least 18 inches between deflectors and storage, drawn as a blocked spray.
Pump room: 40°F minimum, 70°F for a diesel without an engine heater, checked weekly.
Pump room: 40°F minimum, 70°F for a diesel without an engine heater, checked weekly.

Swipe to see more →

These are real pages from the book. The table of contents is the full one: 9 parts and 59 topics.

The Problem Isn't You. It's How It Was Explained to You.

You're in the riser room in front of an OS&Y valve. The inspector next to you asks: is it fully open, and what else do you check on it?

You've worked on that valve for years. But the standard gives you the answer in paragraphs and tables, and with someone watching, paragraphs don't come back.

OS&Y: stem out = open, stem flush = closed, plus the 5 inspection points

In the book, the OS&Y is one page: the valve drawn twice, stem out means open, stem flush means closed, and the 5 inspection points numbered around it.

The main drain, the dry pipe valve, the inspector's test, the gauges and the fire pump room work the same way. Each one has its own page.

You look at the valve, picture the page, and give the answer without opening the standard.

COMPARE FOR YOURSELF

Same Topic, Two Ways to Study It

THIS
  • The standard: line after line of text
  • Frequencies explained only with words and tables
  • You walk into the inspection still unsure
Inspection, testing and maintenance activities shall be performed at the intervals established for each component, wherein the designated frequency is to be interpreted according to defined tolerance ranges. Activities classified as quarterly are understood to occur at intervals of not less than two and not more than four months, while semiannual activities fall between four and eight months and annual activities between nine and fifteen months, subject to the provisions applicable to each system type, the component in question and any additional requirements of the authority having jurisdiction.
FOR THIS
  • Quarterly 2–4, semiannual 4–8, annual 9–15 months: one drawn chart
  • The intervals in one box
  • You know the window before the AHJ asks
Quarterly = 2–4 months apart · Semiannual = 4–8 · Annual = 9–15
CONTENTS

Take a Look at the 9 Parts and 59 Topics

The system at a glance, the frequency chart, valves, gauges and the main drain, alarms and the inspector's test, dry, preaction, deluge and antifreeze, heads and pipe, fire pumps, tanks and impairments, and review and exam prep: 63 pages, all illustrated.

IThe System at a Glance · pp. 5-10
  1. Inspect, Test, Maintain: Three Different Jobs
  2. One Riser, Every Part Labeled
  3. Wet, Dry, Preaction, Deluge Side by Side
  4. Who Does What: Owner, Inspector, AHJ
  5. Hazard Classes in One Picture
  6. Critical, Noncritical, Impairment
IIThe Frequency Chart · pp. 11-16
  1. Every Frequency on One Chart
  2. The Weekly and Monthly Rounds
  3. The Quarterly List
  4. The Annual Visit
  5. The 3-Year and 5-Year Items
  6. Records: What to Keep and for How Long
IIIValves · pp. 17-23
  1. OS&Y: Read the Stem
  2. PIV, Wall PIV and Butterfly Valves
  3. Sealed, Locked or Supervised: Why It Changes the Interval
  4. Full Valve Operation, Every Year
  5. Tamper Switch Test
  6. Check Valves and Backflow Preventers
  7. Pressure Reducing and Relief Valves
IVGauges and the Main Drain · pp. 24-29
  1. Where the Gauges Go and What Each One Tells You
  2. Reading a Gauge Without Mistakes
  3. Main Drain Test in 6 Steps
  4. Worked Example: 72 psi Static, 58 psi Residual
  5. What a Bad Reading Is Telling You
  6. Wet Gauge Higher Than Supply: Normal or Not?
VAlarms and the Inspector's Test · pp. 30-33
  1. Vane Flow Switch vs Pressure Switch
  2. Inspector's Test Connection
  3. Waterflow Alarm Test in 5 Steps
  4. Water Motor Gong and Alarm Valve Trim
VIDry, Preaction, Deluge and Antifreeze · pp. 34-41
  1. Dry Pipe Valve: Air Holds Water Back
  2. Priming Water, Low Air Alarm, Quick-Opening Devices
  3. Partial Trip Test, Annual
  4. Full Flow Trip Test and Water Delivery Time
  5. Low Points and Auxiliary Drains
  6. Preaction: Single, Double, Non-Interlock
  7. Deluge Valve and Open Heads
  8. Antifreeze Systems: The Annual Sample
VIIHeads and Pipe · pp. 42-49
  1. Anatomy of a Sprinkler Head
  2. Temperature Colors: Bulbs and Frames
  3. Good Head vs Bad Head
  4. Clearance and Obstructions
  5. Spare Head Cabinet
  6. When Heads Get Lab Tested or Replaced
  7. Pipe, Fittings and Hangers
  8. Internal Assessment and Obstruction Investigation
VIIIFire Pumps, Tanks, Standpipes and Impairments · pp. 50-58
  1. The Fire Pump Room at a Glance
  2. No-Flow (Churn) Test in Order
  3. Annual Flow Test: Churn, 100%, 150%
  4. Diesel Driver Checks
  5. Water Tanks
  6. FDC, Standpipes and Hose Valves
  7. Private Hydrants and Underground Mains
  8. Impairments: Tag, Notify, Fire Watch
  9. Restoring the System
IXReview and Exam Prep · pp. 59-63
  1. How the Inspection and Testing Exam Is Built
  2. Finding Answers Fast in the Standard
  3. Frequencies People Mix Up Most
  4. Filling the Report Without Blank Fields
  5. The Night-Before Checklist

One Page, One Topic, All Clear

Think of it this way:

You open the main drain with the building owner standing next to you. The static gauge settles, the residual drops, and you have to log both and say whether the number looks right.

You open the book to the main drain page and see the 6 steps numbered in order, the two gauges drawn, and a worked example: 72 psi static, 58 psi residual.

Vane and pressure waterflow switches: semiannual test, retard set per manufacturer, signal within 90 s.

The same goes for the OS&Y, the dry pipe valve, the inspector's test, the head temperature colors and the churn test: each one on its own page.

Sprinkler Inspection Illustrated has 9 parts and 59 topics, all drawn, and it ends with an exam review section and a night-before checklist.

What you see drawn, you don't have to memorize.

What's Inside Sprinkler Inspection Illustrated:

Ipp. 5-10

The System at a Glance

Inspect vs test vs maintain, one riser with every part labeled, wet, dry, preaction and deluge side by side, who does what, hazard classes and impairments.

IIpp. 11-16

The Frequency Chart

Every frequency on one chart, from weekly rounds to the 3- and 5-year items, plus the records to keep, so you never have to guess whether a test is late.

IIIpp. 17-23

Valves

OS&Y stems, PIVs and butterfly valves, sealed vs supervised, annual full operation, the tamper switch test, check valves, backflow preventers, pressure reducing and relief valves.

IVpp. 24-29

Gauges and the Main Drain

Where each gauge sits and the main drain in 6 steps, with a worked 72/58 psi example, so you can log both readings and say if they look right.

Vpp. 30-33

Alarms and the Inspector's Test

Vane vs pressure flow switches, the inspector's test connection, the waterflow alarm test in 5 steps, the water motor gong and alarm valve trim.

VIpp. 34-41

Dry, Preaction, Deluge and Antifreeze

The dry pipe valve, priming water and quick-opening devices, partial and full trip tests, low point drains, preaction types, deluge and the antifreeze sample.

VIIpp. 42-49

Heads and Pipe

Head anatomy, temperature colors, good vs bad heads, clearance, the spare head cabinet, when heads get tested or replaced, pipe, hangers and internal assessments.

VIIIpp. 50-58

Fire Pumps, Tanks, Standpipes and Impairments

The pump room, churn and annual flow tests, diesel checks, tanks, FDCs and standpipes, private hydrants, impairments and restoring the system.

IXpp. 59-63

Review and Exam Prep

How the exam is built, finding answers fast in the standard, the frequencies people mix up most, a complete report and the night-before checklist.

At the end of the book: An exam review section, the frequencies people mix up most and a night-before checklist.

Plus: 2 Free Books

Water-Based ITM Practice Questions: Exam-Style, Answers Explained

BONUS 1: «Water-Based ITM Practice Questions: Exam-Style, Answers Explained»

Value on its own: US$ 17.90

Lets you test yourself on frequencies, valves, gauges and test procedures before exam day, so you know which topics to go back to.

The 15 Most Common Sprinkler Inspection Mistakes: Before & After Cards

BONUS 2: «The 15 Most Common Sprinkler Inspection Mistakes: Before & After Cards»

Value on its own: US$ 14.90

Shows the mistakes inspectors make most often, from a valve left partly closed to a misread gauge, each one drawn next to the correct version so you can review them at a glance.

Sprinkler Inspection Illustrated with 2 Free Books

  • Sprinkler Inspection Illustrated: 63 illustrated pagesUS$ 63
  • BONUS 1: Water-Based ITM Practice Questions: Exam-Style, Answers ExplainedUS$ 17.90
  • BONUS 2: The 15 Most Common Sprinkler Inspection Mistakes: Before & After CardsUS$ 14.90
  • High-resolution PDF to printIncluded
Total value US$ 95.80
YOUR PRICE:
US$ 27
You save US$ 68.80
YES, I WANT SPRINKLER INSPECTION ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

Secure purchaseEncrypted payment30-day guarantee

PDF by email: We email you Sprinkler Inspection Illustrated as a PDF, together with the two free books. It's a single payment: no installments, no extra charges.

Who This Book Is For

You're moving from fitting into inspections

You're moving from fitting into inspections

You already know how a riser goes together. The book shows you what gets inspected, what gets tested and how often, one drawing per topic.

Your inspection and testing exam is coming up

Your inspection and testing exam is coming up

You review frequencies, valves, gauges and test procedures at a glance, then check yourself with the exam-style practice questions.

You already run the riser room

You already run the riser room

Weekly and monthly rounds, the gauge checks, the main drain and the report fields all have a page, so you do them in the same order every time.

Everything You Get Today

US$ 95.80US$ 27
YES, I WANT SPRINKLER INSPECTION ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

30DAYS
GUARANTEE

30-Day Guarantee

Try Sprinkler Inspection Illustrated for 30 days, bonus books included.

We refund everything if the file won't open, if the book isn't what you see here, if you were charged twice or if the email doesn't arrive. Just email us.

You pay once. No subscriptions.

Frequently Asked Questions

Is this for me if I already work as a sprinkler fitter or inspector?

Yes. It doesn't explain what a pipe is. It goes straight to valves, gauges, tests and frequencies, all drawn. Unlike the standard or ten different videos, each topic sits on one page, always in the same order, so you find it again in seconds.

Where does the content come from?

It's checked against the 2023 edition of NFPA 25, with NFPA 13 and NFPA 20 for reference, and against the published content outline of the NICET water-based inspection and testing program. If your exam or your AHJ uses a different edition, check the intervals against that edition: the book tells you where to look in the standard.

Is this official material?

No. It's an independent study book. It isn't affiliated with or endorsed by NFPA, NICET or any authority having jurisdiction, and it doesn't reproduce the standard's text or tables. It doesn't give you a certificate or count toward any certification: it's what you study with before the exam.

Does it replace a course or training?

No. It's material for studying and review. It doesn't replace formal training, supervised field work or the standard itself.

Are the practice questions the ones on the exam?

No. They're written for this book, in exam style, so you can test yourself. They aren't official exam questions.

When and how do I get it?

In PDF by email, sent to the address you enter at checkout.

Do I have to pay every month?

No. It's a one-time payment.

Can I get it on paper?

No printed copy is shipped. You get a PDF by email that's ready to print, so you can keep it in the truck or the riser room.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

Before You Close This Page

No more rereading the standard and retaining nothing.

The OS&Y, the main drain, the dry valve: you see each one drawn, and that's it.

You walk into the exam or the riser room knowing where everything is.

Drawings make studying faster.

The book is right below.

One-time payment: US$ 27 · Guarantee: 30 days · PDF by email

YES, I WANT SPRINKLER INSPECTION ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.